Benefits

Infinity-Lock Button System is designed to enable meticulous care of the tissue structures in the shoulder.

  • No drill hole through the delicate coracoid, reducing risk of fracture.
  • Instrumentation: CC-Hook dedicated coracoid passer for minimal soft-tissue damage.
  • Broad tape for reduced likelihood of bone abrasion.
  • 4 mm clavicle vertical tunnel, no A-P drilling.

The tape construct has an open-weave structure, facilitating tissue in-growth and on-growth. Tissue graft augmentation can be used but is not needed, eliminating autograft morbidity and allograft cost issues.

The one-size-fits-all design and single-use instrument reduce inventory and instrument-kit complexity as well as eliminating the risk of mis-sizing.

  • Studies show good clinical and radiological outcomes
  • Pain reduction, anatomic shoulder reduction and enabling return to work or sport
  • The device has low stretch and maintains high strength under repeated long-term loading

Infinity-Lock Button System

  1. The implant is passed around the coracoid process and both limbs are passed through the loop
  2. Both limbs of the Tape are passed through the 4 mm diameter bone tunnel one at a time
  3. Single low-profile Button is used to anchor the Tape to the bone
  4. Secured with a surgeon’s knot posteriorly

Clinical Data Summary

There are several studies on the Infinity-Lock Button System, from different centres, all with excellent results.

  • Series of 15 patients, Rockwood Grade III AC joint dislocations, 18 month follow-up.
  • Series of 15 patients, Rockwood Grade IV, V acute and Grade III chronic, controlled, followed for minimum 3 months.
  • Series of mixed grade AC joint dislocations, 15 cases.

The studies used different function scoring systems but showed good improvement. Romano et al reported CMS scores of 95 at 18-month follow-up. Loukovitis et al used the Nottingham clavicle score, the patients treated with Infinity-Lock Button System had a mean score of 80 at follow-up, the control group score was 69. Chowdhury et al used the Oxford score, recording 40.5 (maximum 48) improved from 16.2 pre-operatively (no control group).

Two studies also measured the reduction, with 7.4 mm and 8.2 mm mean reductions in clavicle-coracoid distance. There were only two instances of loss of reduction in the 45 cases across all three reports.

The Infinity-Lock Button System is indicated for patients with acromioclavicular separations resulting from disruption to the coracoclavicular ligaments.

To view the instructions for use please visit our IFU library.

Instructions for Use

102-1089 Infinity-Lock Button System, includes:

  • Infinity-Lock Tape, 7 mm x 240 mm
  • Infinity-Lock Button, 4 mm x 12 mm
  • Cannulated drill bit, plain shank to fit Jacobs Chuck, 4.0 mm diameter x 120 mm
  • Guidewire, 2.0 mm diameter x 150 mm

Optional Disposable Instrument:

  • 202-1411 CC-Hook, with a curved end, Left
  • 202-1413 CC-Hook, with a curved end, Right